KCS Building Analysis - EN56 mục hướng dẫn
Mục lục hướng dẫn
Cập nhật 15/10/2026

If We Cannot Compare Every Structural Model, How Can We Trust the Results?

Are we approaching this issue with the assumption that ETABS always produces correct results? In reality, we have not independently verified ETABS itself. Even when using ETABS, engineers cannot manually reproduce every step of the analysis process to establish with absolute certainty that every result generated by ETABS is correct.

The most practical approach is to use specific structural models with identical input data and compare the results obtained from KCS Building Analysis (KBA) and ETABS. A comparison study is already available at the following link for users to review:

KCS Building Analysis – Results Verification and Comparison

Agreement between programs supports the comparison for the models and settings tested; it does not establish that every model or result is correct.

If you have been using ETABS and accept its results as a valid reference, the same principle should also apply to KBA: verify the software using real structural models and evaluate the consistency and accuracy of its results, rather than automatically assuming that one program is correct while requiring the other to prove its correctness from scratch.

Simply put, the same standards of verification and evaluation should be applied to both ETABS and KBA.

If you have doubts about KBA, you are welcome to use a specific structural model to compare its results with those from ETABS, rather than questioning its reliability solely because it is not feasible to manually calculate every internal force generated by the software. Likewise, if the inability to independently reproduce every calculation is considered a reason to question KBA, the same concern should logically apply to ETABS.

Ultimately, correct software calculations do not necessarily mean that the structural model itself is correct.

Engineers must still follow a proper model verification and result evaluation process, including checking:

  • Applied loads and load combinations.
  • Structural connections and restraints.
  • Boundary conditions.
  • Material properties.
  • Section properties.
  • Modeling assumptions and structural behavior.

For example, simply omitting a load or failing to assign a required restraint may not prevent the software from successfully completing the analysis. However, the resulting calculations would no longer accurately represent the actual structural problem.

Therefore, when evaluating either KBA or ETABS, it is important to distinguish between the responsibility of the software and the responsibility of the structural engineer.

The software is responsible for performing calculations based on the structural model and input data provided, while the engineer remains responsible for verifying the model, assessing the reasonableness of the results, and making the final engineering judgments.

This is also why KCS encourages users to explore KBA, test it using their own real-world structural models, and independently compare its analysis results with those obtained from ETABS.

Our objective is not to ask users to trust KBA without verification, but to encourage a fair, consistent, and evidence-based evaluation of its capabilities and reliability.